Chemicals & Materials
Instrument selection for process support, incoming-material screening and release testing of chemical and material products.
8 measurement tasks · 7 instruments · 4 notes
Explore workflowK Series / Double beam
A double-beam member of the K Series, with touchscreen operation for laboratory UV-Vis measurement workflows.
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents| Optical System | Double Beam, Grating 1200 lines/mm |
|---|---|
| Wavelength Range | 190-1100 nm |
| Spectral Bandwidth | 2nm |
| Wavelength Accuracy | ±0.1nm@656.1nm, ±0.3nm@all |
| Wavelength Repeatability | <=0.1nm |
| Photometric Accuracy | 0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A) |
| Photometric Repeatability | ≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A) |
| Photometric Range | 0-200%T, -0.3~3A, 0-9999C |
| Stray Light | <=0.03%T@220nm, 360nm |
| Stability | ±0.0003A/h @500 nm |
| Baseline Flatness | ±0.002A |
| Noise | 0.0005A@500nm |
| Work Mode | T, A, C, E |
| Scanning Speed | Hi, Med, Low (Max. 3000nm/min) |
| Wavelength Setting | Auto |
| Display | 10.1 inches Touch Screen |
| Light Source | Deuterium & Tungsten lamp |
| Detector | Silicon Photodiode |
| Cuvette Holder | 10mm single hole cell holder |
| Output | USB drive, USB host, RS232 |
| Power | AC 110-220V 50-60Hz |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelWhat this instrument is designed to do, in plain terms.
The K9000 uses a double-beam optical system, measuring the sample and reference paths together. It suits laboratories that need reference correction during longer measurement series or work with changing lamp output. The interface and wavelength range match the rest of the K Series, so methods can be transferred between instruments in the same family.
Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.
No Optional Accessaries are published for this model. Confirm availability with our team.
Data export and user-access functions depend on the installed software version. Confirm the current package and any documentation required for your quality system.
Confirm requirements with our team before the final order.
A double-beam system measures the reference at the same time as the sample, which helps when lamp output drifts during a long run.
The interface is shared across the series, but always re-verify a method on the target instrument before routine use.
See how the model is positioned for real measurement tasks.
Instrument selection for process support, incoming-material screening and release testing of chemical and material products.
8 measurement tasks · 7 instruments · 4 notes
Explore workflowInstrument configuration for pharmaceutical quality control: assay by UV-Vis, water content, melting point, titration and weighing.
8 measurement tasks · 7 instruments · 4 notes
Explore workflowLet’s talk about your application
Share your sample, measurement requirements and preferred configuration.