Industrial Water
Instrument selection for boiler feed, cooling water, process water and effluent in industrial plants.
10 measurement tasks · 7 instruments · 4 notes
Explore workflowIC Series
This is the latest integrated ion chromatograph with dual anion and cation channels
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents| All-PEEK pump head pressure range | 0-35 MPa |
|---|---|
| Flow setting range | 0.001-10.000 ml/min |
| Flow setting error | <0.1% (at 1.0 ml/min) |
| Flow accuracy | RSD <0.1% |
| Pressure sensor | Pressure display accuracy 0.1 MPa |
| Overpressure protection | The pump automatically shuts down and an alarm sounds when the operating pressure exceeds or falls below the set upper or lower limit |
| Pressure range | 0-35 MPa |
| Dynamic suppression capacity | 100µeq/min |
| Suppression background | 0.6µS/cm |
| Suppression background noise | 6nS/cm |
| Suppressor dead volume | 60µL |
| Current range | 0-150mA |
| Current setting increment | 0.1mA |
| Anions | Simultaneously analyze anions such as F-, Cl-, Br-, NO3-, NO2-, |
| Cations | Simultaneously analyze Li+, Na+, NH4+, K+, Mg2+, and Ca2+ in a single injection |
| Temperature control range | 5-65°C |
| Temperature setpoint error | ≤ 0.1°C |
| Temperature control stability error | ≤ 0.1°C • Compatible with 250mm and 150mm ion chromatography columns |
| Conductivity detection range | 0-15,000µs |
| Detection cell volume | ≤0.3µL |
| Baseline noise | ≤0.5%FS |
| Baseline drift | <±0.8%FS/30min |
| Linear correlation coefficient | ≥0.999 |
| Detection limits | (µg/g) Cl ≤0.0005; NO3- ≤0.005; Na+ ≤0.0005; Ca2+ ≤0.010 |
| Retention time repeatability error | NO3-, SO42-, Na+, and Ca2+ ≤1.0% |
| Eluent range | 0.1-100 mM |
| Flow rate range | 0.1-5 ml/min |
| Maximum pressure | 30 MPa |
| Gradient precision | 0.2% |
| Gradient accuracy | 0.15% |
| Eluent type | KOH/methanesulfonic acid/potassium carbonate |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelWhat this instrument is designed to do, in plain terms.
IC hope
Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.
Ask for an itemised quotation that separates standard items from options.
See how the model is positioned for real measurement tasks.
Instrument selection for boiler feed, cooling water, process water and effluent in industrial plants.
10 measurement tasks · 7 instruments · 4 notes
Explore workflowInstrument selection for drinking water, surface water, groundwater and treated wastewater — from field parameters to trace metals.
9 measurement tasks · 8 instruments · 4 notes
Explore workflowLet’s talk about your application
Share your sample, measurement requirements and preferred configuration.