Food & Beverage
Routine quality-control instruments for food and beverage laboratories: colour, moisture, sample mass, acidity and sodium.
8 measurement tasks · 7 instruments · 4 notes
Explore workflow2 models
Two single-beam spectrophotometers, UV1600 and UV1610, with a 190-1000 nm range, 1 nm wavelength accuracy and 0. 5 percent T photometric accuracy.
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents| Optical System | Single Beam, Grating 1200 lines/mm |
|---|---|
| Wavelength Range | 190-1000nm |
| Wavelength Accuracy | 1nm |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelModel comparison
Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.
| Parameter | UV1600 | UV1610 |
|---|---|---|
| Optical System | Single Beam, Grating 1200 lines/mm | Single Beam, Grating 1200 lines/mm |
| Wavelength Range | 190-1000nm | 190-1000nm |
| Spectral Bandwidth | 2 nm | 4 nm |
| Wavelength Accuracy | 1nm | 1nm |
| Wavelength Repeatability | ≤0.5nm | ≤0.5nm |
| Photometric Accuracy | 0.5%T | 0.5%T |
| Photometric Repeatability | 0.3%T | 0.3%T |
| Photometric Range | 0-200%T, -0.3~3A, 0-9999C | 0-200%T, -0.3~3A, 0-9999C |
| Stray light | 0.3%T | 0.3%T |
| Stability | ±0.002A/h@500nm | ±0.002A/h@500nm |
| Baseline Flatness | ±0.002 A | ±0.002 A |
| Noise | ±0.001 A | ±0.001 A |
| Work Mode | T, A, C, E | T, A, C, E |
| Wavelength Setting | Auto | Auto |
| Display | 128*64 LCD | 128*64 LCD |
| Light Source | Deuterium & Tungsten lamp | Deuterium & Tungsten lamp |
| Detector | Silicon Photodiode | Silicon Photodiode |
| Cuvette Holder | 10mm manual 4-cell holder | 10mm manual 4-cell holder |
| Output | USB, RS232 | USB, RS232 |
| Power | AC 110-220V 50-60Hz | AC 110-220V 50-60Hz |
Shaded labels mark the specifications that differ between models.
What this instrument is designed to do, in plain terms.
The 1600 Series Single Beam Spectrophotometer covers 2 models, UV1600 to UV1610. The comparison table lists the values that differ across the range.
Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.
See how the model is positioned for real measurement tasks.
Routine quality-control instruments for food and beverage laboratories: colour, moisture, sample mass, acidity and sodium.
8 measurement tasks · 7 instruments · 4 notes
Explore workflowLet’s talk about your application
Share your sample, measurement requirements and preferred configuration.