4 models

AA 7800 Atomic Absorption Spectrometer

Four atomic absorption spectrometers from AA 7804 to AA 7828 sharing a Czerny-Turner monochromator, a 1800 lines/mm grating and a 190-900 nm range.

Category Atomic Absorption Spectrometer In production
  • Comprehensive and safe intelligent gas control module.
  • Excellent full band deuterium lamp background correction technology and high-performance self absorption double background correction.
  • Fully automatic instrument control, light source supports high-performance element lamp, and can be completed quickly with one key.
  • Original lamp position eight lamp holder 360 degree rotation design.
  • Novel atomizer and intelligent elevator.
AA 7800 Atomic Absorption Spectrometer core specifications
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Holographic diffraction with 1800 lines/mm
Wavelength Range 190-900 nm

Send your sample type and method, and we will confirm the configuration and current lead time.

Ask about this model

sales@yoke-fac.com

Model comparison

AA 7800 Atomic Absorption Spectrometer range at a glance

Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.

AA 7800 Atomic Absorption Spectrometer — 4 models
ParameterAA 7804AA 7808AA 7818AA 7828
Optical SystemSingle BeamSingle BeamSingle BeamDouble Beam
Wavelength Repeatability±0.1nm±0.1 nm±0.05 nm±0.05 nm
Wavelength Accuracy±0.3 nm±0.2 nm±0.15 nm±0.15 nm
LampAutomated 4-lamp turretAutomated 8-lamp turretAutomated 8-lamp turretAutomated 8-lamp turret
Static Baseline Drift (Cu)≤0.004A/30 min≤0.003A/30 min≤0.002A/30 min≤0.002A/30 min
Dynamic Baseline Drift (Cu)≤0.006A/15 min≤0.005A/15 min≤0.004A/15 min≤0.004A/15 min
Background CorrectionDeuterium (D2) Background CorrectionDeuterium (D2) Background CorrectionDeuterium (D2) Background Correction and Self-absorption Background CorrectionDeuterium (D2) Background Correction and Self-absorption Background Correction
Flame · Characteristic Concentration≤0.04ug/ml≤0.035ug/ml≤0.035ug/ml≤0.035ug/ml
Flame · Detection Limit (Cu)≤0.008ug/ml≤0.006ug/ml≤0.004ug/ml≤0.004ug/ml
Flame · Repeatability (Cu)RSD≤1%RSD≤0.6%RSD≤0.5%RSD≤0.5%
Graphite Furnace · Characteristic AmountCd≤1pg, Cu≤22pgCd≤0.8pg, Cu≤20pgCd≤0.8pg, Cu≤20pgCd≤0.8pg, Cu≤20pg
Graphite Furnace · Detection Limit (Cu)Cd≤1.5pg, Cu≤20pgCd≤1.0pg, Cu≤10pgCd≤0.8pg, Cu≤5pgCd≤0.8pg, Cu≤5pg
Graphite Furnace · Repeatability (Cu)RSD≤4%RSD≤3%RSD≤2.5%RSD≤2.5%

Overview

What this instrument is designed to do, in plain terms.

The AA 7800 Atomic Absorption Spectrometer covers 4 models, AA 7804 to AA 7828. The comparison table lists the values that differ across the range.

  • Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.
  • Comprehensive and safe intelligent gas control module.
  • Excellent full band deuterium lamp background correction technology and high-performance self absorption double background correction.
  • Fully automatic instrument control, light source supports high-performance element lamp, and can be completed quickly with one key.
  • Original lamp position eight lamp holder 360 degree rotation design.
  • Novel atomizer and intelligent elevator.
  • Simple, professional, automatic and fully operated RG WIN AAS workstation software under MS window system.

Accessaries

Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.

Standard Accessaries

Ask for an itemised quotation that separates standard items from options.

Optional Accessaries

  • Auto sampler
Specifications can depend on the selected configuration. Confirm the current datasheet, accessories and software version before purchase.

Product documentation

No public documents are linked to this model yet.

Request current documents

Applications for this instrument.

See how the model is positioned for real measurement tasks.

01 / Industry

Industrial Water

Instrument selection for boiler feed, cooling water, process water and effluent in industrial plants.

10 measurement tasks · 7 instruments · 4 notes

Explore workflow
02 / Water

Water & Environment

Instrument selection for drinking water, surface water, groundwater and treated wastewater — from field parameters to trace metals.

9 measurement tasks · 8 instruments · 4 notes

Explore workflow

Let’s talk about your application

Find the right instrument for your application.

Share your sample, measurement requirements and preferred configuration.

Contact our team