UM Series Microvolume Spectrophotometer
Minimal sample volume required (0. 3–2 μL); UV-Vis Full-Wavelength Scanning (200–850 nm)
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents| Minimum sample volume | 0.3-2μl |
|---|---|
| Wavelength Accuracy | ±1.0nm |
| Wavelength Repeatability | ±0.5nm |
| Detection time | < 3s |
| Absorbance Range | Ultra-micro Mode: 0 - 800 Abs (@10mm); Cuvette Mode 0 - 16 Abs (@10mm) |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelOverview
What this instrument is designed to do, in plain terms.
The UM Series Microvolume Spectrophotometer covers 4 models, UM-100 to UM-330. The comparison table lists the values that differ across the range.
- Minimal sample volume required (0. 3–2 μL); UV-Vis Full-Wavelength Scanning (200–850 nm)
- No preheating required, testable at any time.
- Fast detection speed; Display the concentration value directly
- The sample does not need to be diluted; Data statistics software is easy to master and use.
- Built-in optical fiber prevents fiber breakage caused by external collision, which would otherwise lead to inaccurate measurement results.
- Data Output Ports: Equipped with multiple data interfaces for free export of test data and connection to computer software.
- Equipped with automatic detection function (results are generated automatically when the detection chamber is closed)
- The standard curve features multiple fitting functions: linear, interpolation, second-order polynomial and third-order polynomial.
- Flexible kinetic module enabling kinetic detection in 5 stages with customizable delay time, interval time and number of detections for each stage.
- One-click export of scan result spectra; built-in Wi-Fi for remote operation and unlimited result printing; comes with a high-definition display and full touch control.
- No warm-up on startup, ready to use instantly; data collection for the 190nm-1100nm wavelength range can be completed in 1. 0-5. 0 seconds.
- Equipped with a constant temperature device, it effectively eliminates interference from temperature fluctuations for more accurate test results; stabilizes the activity of temperature-sensitive samples (e.g., enzymes and nucleic acids) to suit special experiments; and allows temperature setting as required, expanding the instrument's application scenarios.
- Extensive accessories are optional, such as Liquid injection abnormality detection function, Intelligent sample detection function (ensures accurate sample concentration and quality, guaranteeing experimental accuracy and optimal results)., built-in printer.
Accessaries
Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.
Standard Accessaries
Ask for an itemised quotation that separates standard items from options.
Optional Accessaries
- Liquid injection abnormality detection function
- Intelligent sample detection function (ensures accurate sample concentration and quality, guaranteeing experimental accuracy and optimal results)
- built-in printer