4 models
K Series Flashing Xenon Lamp Spectrophotometer
Four double-beam spectrophotometers from K8000-X to K9001-X with a Hamamatsu flashing xenon lamp, so measurement starts without a warm-up period.
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents- Functions include Photometric measurement, Quantitative measurement, Kinetics, Spectrum scan, DNA/Protein test, multi-wavelength test, etc
- In-house massive memory is capable of saving up to 1024M for test data & working curves.
- Supports USB storage.
- Large sample chamber can accommodate 5-100mm cuvettes of all kinds.
- Extensive accessories are optional, such as auto 8-cell holder, film holder, tube rack, peltier/sipper system, integrating sphere, reflection accessory, built-in printer, 21 CFR compliant software…
| Optical System | Double Beam, Grating 1200 lines/mm |
|---|---|
| Wavelength Range | 190-1100 nm |
| Wavelength Accuracy | ±0.3nm |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelModel comparison
K Series Flashing Xenon Lamp Spectrophotometer range at a glance
Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.
| Parameter | K8000-X | K8001-X | K9000-X | K9001-X |
|---|---|---|---|---|
| Display | 7-inch Color Screen | 7-inch Color Screen | 10.1-inch Touch Screen | 10.1-inch Touch Screen |
| Optical System | Double Beam, Grating 1200 lines/mm | Double Beam, Grating 1200 lines/mm | Double Beam, Grating 1200 lines/mm | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190-1100 nm | 190-1100 nm | 190-1100 nm | 190-1100 nm |
| Spectral Bandwidth | 2nm | 1nm | 2nm | 1nm |
| Wavelength Accuracy | ±0.3nm | ±0.3nm | ±0.3nm | ±0.3nm |
| Wavelength Repeatability | ≤0.1nm | ≤0.1nm | ≤0.1nm | ≤0.1nm |
| Photometric Accuracy | 0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A) | 0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A) | 0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A) | 0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A) |
| Photometric Repeatability | ≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A) | ≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A) | ≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A) | ≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A) |
| Photometric Range | 0-200%T, -0.3~3A, 0-9999C | 0-200%T, -0.3~3A, 0-9999C | 0-200%T, -0.3~3A, 0-9999C | 0-200%T, -0.3~3A, 0-9999C |
| Stray Light | ≤0.03%T@220nm, 360nm | ≤0.03%T@220nm, 360nm | ≤0.03%T@220nm, 360nm | ≤0.03%T@220nm, 360nm |
| Stability | ±0.0005A/h@500nm | ±0.0005A/h@500nm | ±0.0003A/h@500nm | ±0.0003A/h@500nm |
| Baseline Flatness | ±0.002A | ±0.001A | ±0.002A | ±0.001A |
| Noise | 0.0005A@500nm | 0.0005A@500nm | 0.0005A@500nm | 0.0005A@500nm |
| Work Mode | T, A, C, E | T, A, C, E | T, A, C, E | T, A, C, E |
| Scanning Speed | Hi, Med, Low (Max. 3000nm/min) | Hi, Med, Low (Max. 3000nm/min) | Hi, Med, Low (Max. 3000nm/min) | Hi, Med, Low (Max. 3000nm/min) |
| Wavelength Setting | Auto | Auto | Auto | Auto |
| Light Source | Xenon Lamp | Xenon Lamp | Xenon Lamp | Xenon Lamp |
| Detector | Silicon Photodiode | Silicon Photodiode | Silicon Photodiode | Silicon Photodiode |
| Cuvette Holder | 10mm single hole cell holder | 10mm single hole cell holder | 10mm single hole cell holder | 10mm single hole cell holder |
| Output | USB drive, USB host, RS232 | USB drive, USB host, RS232 | USB drive, USB host, RS232 | USB drive, USB host, RS232 |
| Power | AC 110-220V 50-60Hz | AC 110-220V 50-60Hz | AC 110-220V 50-60Hz | AC 110-220V 50-60Hz |
Shaded labels mark the specifications that differ between models.
Overview
What this instrument is designed to do, in plain terms.
The K Series Flashing Xenon Lamp Spectrophotometer covers 4 models, K8000-X to K9001-X. The comparison table lists the values that differ across the range.
- High quality flashing xenon lamp is from Hamamatsu, which can start to test directly without preheating. The lamp can be used at least 3-year.
- Functions include Photometric measurement, Quantitative measurement, Kinetics, Spectrum scan, DNA/Protein test, multi-wavelength test, etc.
- In-house massive memory is capable of saving up to 1024M for test data & working curves.
- Supports USB storage. The USB port can be used for data transfer and exporting to Excel for further processing, analysis and storage.
- Large sample chamber can accommodate 5-100mm cuvettes of all kinds.
- Extensive accessories are optional, such as auto 8-cell holder, film holder, tube rack, peltier/sipper system, integrating sphere, reflection accessory, built-in printer, 21 CFR compliant software, etc.
Accessaries
Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.
Standard Accessaries
- 10mm glass cuvette x 4
- 10mm quartz cuvette x 2
- Power cord
- User's Manual
- PC software
Optional Accessaries
- auto 8-cell holder
- film holder
- tube rack
- peltier/sipper system
- integrating sphere
- reflection accessory
- built-in printer
- 21 CFR compliant software
Let’s talk about your application
Find the right instrument for your application.
Share your sample, measurement requirements and preferred configuration.