GC- Series

GC-7860 Gas Chromatograph

Gas circuit manually and full electronic gas circuit (EPC/EFC) control is optional, networking communication (Ethernet interface IEEE802. 3), computer online full control operation

Model GC-7860 Category Gas Chromatograph In production
GC-7860 core specifications
EPC working mode constant current, constant voltage, shunt mode
Program pressure control 4 stage
EPC working gases N2, H2, Air, He, Ar
EPC control range pressure 0~ 0.6kpa flow 0~100sccm or 0~500sccm
EPC control accuracy pressure 0.01Kpa; Flow rate of 0.01 sccm
External events 6-way. auxiliary control 2-way
Temperature control circuit number 8
Oven temperature range room temperature of 4 ℃ ~ 450 ℃ (increment 1 ℃)
Oven temperature programming Rising order 16 order
Rising rate setting 0.1 ~ 39 ℃ / min (ordinary type); 0.1~80℃/min (high-speed type)
Constant temperature time of each order 0~999min (increment: 0.1min)
Programmed cooling 260 ℃ to 50 ℃ only need 6 minutes
Range of temperature Room temperature of 4 ℃ ~ 450 ℃ (increment 1 ℃)
The accuracy of temperature control better than±0.01 ℃
Limit of detection ≦3×10¯¹²g/s
Baseline Noise 5×10¯¹⁴A
Baseline Drift ≦1×10¯¹³A/30min
Linear ≧10⁷
Sensitivity S≧3000mv.ml/mg
Baseline Noise ≦10µv
Baseline Drift ≦30µv/30min
Linear ≧10⁵
Carrier gas velocity stability ≦1%
Linear range 10⁴
Source Ni⁶³
Limit of detection 5ׯ¹²g/s(S) (S in methyl parathion)
Linear range 10⁵(P) 10³(S)
Maximum service temperature 350℃
Detection Method Air-hydrogen flame spectrometry
Optical detector Top photomultiplier
Multiplier voltage Max--700V
Limit of detection (N)≦5×10¯¹²g/s

Send your sample type and method, and we will confirm the configuration and current lead time.

Ask about this model

sales@yoke-fac.com

Overview

What this instrument is designed to do, in plain terms.

  • Gas Chromatography GC-7860 series
  • The GC fully absorbs advanced technology from similar foreign products and adopts industry-leading manufacturing technology and processes, ensuring the reliability and trouble-free operation time of the instrument. It can not only maximize normal operation time and reduce maintenance times, but also be more concise and reasonable in structure, with a more macroscopic and atmospheric appearance; Clear keyboard operation and convenient system control software make it easy to learn and operate. The GC system can be loaded with advanced electronic gas path control (EPC) systems, providing industry-leading excellent quality and reliable results for industry users. The GC has unique network remote transmission and control functions, making it a reality for unmanned, decentralized monitoring, and centralized control of the instrument; The data analysis results can be connected to DCS to complete the statistics, analysis, and monitoring of chromatographic component content, thereby improving the automation of the production process.
  • All injection port and detector gas paths can be controlled by an electronic gas circuit (EPC) to provide better retention time and peak area accuracy. The users can set various parameters such as gas flow rate, external events, temperature, and detector through anti control software, and save all parameters of the analysis method. The digital circuit ensures consistent settings between different operators during each operation. Therefore, users can achieve better retention time reproducibility and more consistent and reliable results, achieving twice the result with half the effort.
  • The GC can be equipped with a liquid automatic sampler, which uses reverse control software to control various parameters. This will bring better repeatability and improve work efficiency, while eliminating errors caused by manual sampling.
  • Gas circuit manually and full electronic gas circuit (EPC/EFC) control is optional, networking communication (Ethernet interface IEEE802. 3), computer online full control operation.
  • Electronic gas circuit (EPC/EFC) control mode
  • EPC electronic gas circuit control precision is 0. 01mL/min or 0. 01Kpa, which ensures better retention time reproducibility and more consistent and reliable results
  • Support high-speed heating, the maximum rate of 80 ℃ / min; Suitable for rapid analysis
  • Could be up to 450 ℃, suitable for high boiling point the analysis of the sample
  • Support double oven and double rear door opening mode
  • Oven temperature increment 1 ℃, the accuracy of + / – 0. 01 ℃, is close to high-grade imported similar products
  • Diversified injection system; Packed column injection, capillary S/SL injection, valve injection, automatic liquid injection, automatic headspace injection, splitting injection, thermal desorption injection, purge and capture injection are optional
  • Special customized valve system can help users complete complex multidimensional chromatographic analysis tasks. Plus series is a multi-purpose gas chromatography specially designed for multidimensional application analysis and online analysis.
  • Rich detector types, up to three detectors can be installed: TCD, HTCD, uTCD, FID, FPD, ECD, NPD, ZD, PDHID, PID, AID
  • The program supports multiple flow path sample selection MPV system, with automatic identification valve number, automatic cascade judgment, automatic reset, valve position selection, valve position analysis memory function, up to 32 support sample flow path selection
  • Unique network remote transmission and control functions, unattended analysis, decentralized monitoring, centralized control.
  • The data can be connected to DCS system to complete the statistics, analysis and monitoring of chromatographic component content and improve the automation level of production process control
  • Temperature control index:
  • Oven temperature control precision, better than ±0. 01 ℃
  • Sample injector, detector, thermal conductivity pool, methane reformer temperature index:
  • ◎The collecting pole adopts the original cylindrical structure and quartz nozzle
  • ◎Adopt semi-diffused structure
  • ◎Constant current control mode is adopted for power supply
  • HTCD High sensitivity thermal conductivity detector S≧10000mv.ml/mg; Digital amplification 1, 2, 4, 8 times optional
  • ◎Capillary column connecting parts are optional
  • ◎Limit of detection:≦1×10¯¹⁴g/s
  • 5×10¯¹³g/s (P) (P in methyl parathion)

Accessaries

Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.

Standard Accessaries

Ask for an itemised quotation that separates standard items from options.

Optional Accessaries

  • Electronic gas circuit (EPC/EFC) control
  • Packed column injection
  • Capillary S/SL injection
  • Valve injection
  • Automatic liquid injection
  • Automatic headspace injection
  • Splitting injection
  • Thermal desorption injection
  • Purge and capture injection
  • Digital amplification 1, 2, 4, 8 times
  • Capillary column connecting parts
Specifications can depend on the selected configuration. Confirm the current datasheet, accessories and software version before purchase.

Product documentation

No public documents are linked to this model yet.

Request current documents

Applications for this instrument.

See how the model is positioned for real measurement tasks.

01 / Materials

Chemicals & Materials

Instrument selection for process support, incoming-material screening and release testing of chemical and material products.

8 measurement tasks · 7 instruments · 4 notes

Explore workflow

Let’s talk about your application

Find the right instrument for your application.

Share your sample, measurement requirements and preferred configuration.

Contact our team