AA Series
AA 7804 Graphite Furnace Spectrometer
Graphite furnace atomic absorption spectrometer with a Czerny-Turner monochromator, a 1800 lines/mm holographic grating and a 190-900 nm wavelength range.
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents- Comprehensive and safe intelligent gas control module.
- Excellent full band deuterium lamp background correction technology and high-performance self absorption double background correction.
- Fully automatic instrument control, light source supports high-performance element lamp, and can be completed quickly with one key.
- Original lamp position eight lamp holder 360 degree rotation design.
- Novel atomizer and intelligent elevator.
| Optical System | Single Beam |
|---|---|
| Monochromator | Czerny-Turner type, focal lengths at 350mm |
| Grating | Holographic diffraction with 1800 lines/mm |
| Wavelength Range | 190-900 nm |
| Slits | Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm |
| Wavelength Repeatability | ±0.1nm |
| Wavelength Accuracy | ±0.3 nm |
| Lamp | Automated 4-lamp turret |
| Reading Mode | T, A, C |
| Photometric Range | 0-125%, -0.1-3.00A |
| Static Baseline Drift (Cu) | ≤0.004A/30 min |
| Dynamic Baseline Drift (Cu) | ≤0.006A/15 min |
| Background Correction | Deuterium (D2) Background Correction |
| Graphite Furnace · Characteristic Amount | Cd≤1pg, Cu≤22pg |
| Graphite Furnace · Detection Limit (Cu) | Cd≤1.5pg, Cu≤20pg |
| Graphite Furnace · Repeatability (Cu) | RSD≤4% |
| Graphite Furnace · Heating range | Room temperature-3000 °C |
| Graphite Furnace · High power heating range | 1500-3000 °C |
| Graphite Furnace · Slope and holding time | 1-255s |
| Graphite Furnace · Heating rate | Maximum heating rate 2000 °C/s |
| Graphite Furnace · Atomization heating mode | Light-controlled heating, Time-controlled heating, General heating |
| Graphite Furnace · Outer protective gas flow | 1 L/min |
| Graphite Furnace · Inner protective gas flow | 4-speed adjustable (0, 50, 200, 250/min flow) |
| Graphite Furnace · Safety Protection | Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm |
| Auto Sampler | Optional |
| Data Processing · Measuring method | Graphite furnace method, Hydride generation-Atomic absorption method |
| Data Processing · Concentration calculation method | Standard curve method (6 linear/non-linear fitting methods), Standard addition method, Interpolation method |
| Data Processing · Repeat measurement times | 1-30 times, Calculate and give the average value of absorbance/concentration, standard deviation and relative standard deviation |
| Data Processing · Report printing | Parameter printing, Data result printing |
| Dimensions / Weight | 850 x 650 x 550 mm/95kg |
| Ambient Temp. | 10 ~ 35 °C |
| Ambient Humidity | ≦85 % |
| Power | 110/220V, 50/60Hz |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelOverview
What this instrument is designed to do, in plain terms.
AA
- Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.
- Comprehensive and safe intelligent gas control module.
- Excellent full band deuterium lamp background correction technology and high-performance self absorption double background correction.
- Fully automatic instrument control, light source supports high-performance element lamp, and can be completed quickly with one key.
- Original lamp position eight lamp holder 360 degree rotation design.
- Novel atomizer and intelligent elevator.
- Simple, professional, automatic and fully operated RG WIN AAS workstation software under MS window system.
Accessaries
Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.
Standard Accessaries
Ask for an itemised quotation that separates standard items from options.
Optional Accessaries
- Auto sampler
Specifications can depend on the selected configuration. Confirm the current datasheet, accessories and software version before purchase.
Let’s talk about your application
Find the right instrument for your application.
Share your sample, measurement requirements and preferred configuration.