Chemicals & Materials
Instrument selection for process support, incoming-material screening and release testing of chemical and material products.
8 measurement tasks · 7 instruments · 4 notes
Explore workflowGC- Series
Equipped with a 10-inch touchscreen display
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents| Communication | Network communication via an IEEE 802.3 Ethernet interface; the workstation also supports an RS232 communication interface |
|---|---|
| EPC working mode | constant current, constant voltage, split mode |
| EPC working gases | N2, H2, Air, He, Ar |
| EPC control range | pressure 0~ 0.6kpa flow 0~500 sccm |
| EPC control accuracy | pressure 0.01Kpa; Flow rate of 0.01 sccm |
| Remote monitoring | Real-time monitoring of instrument operation, online/offline status, and operating parameters |
| Instrument control | Remotely adjust instrument parameters and control instrument operations, such as ignition (for gas chromatography), sample injection, and analysis |
| Data acquisition and transmission | Real-time chromatographic data acquired by the instrument can be transmitted to the cloud platform |
| Data storage and analysis | The cloud platform stores transmitted data and allows users to view, analyze, and share chromatograms |
| Number of temperature control channels | 10 |
| Temperature control range | Column oven temperature: Ambient temperature +4 °C to 450°C (1°C increments) |
| Temperature control accuracy/stability | ≤0.1% |
| Display resolution | 0.01°C |
| Temperature programming | 23 steps (expandable to an unlimited number of steps) |
| Temperature ramp rate | 0- 40°C/min (adjustment increments: 0.1°C/min) |
| Maximum heating rate | 80°C/min |
| Temperature programming repeatability | ≤0.5% |
| Cooling time | ≤8 min (from 300°C to 50°C, with automatic door opening) |
| Detection Limit | ≤3 × 10⁻¹² g/s (n-hexadecane) |
| Baseline Noise | ≤5×10¯¹⁴A |
| Baseline Drift | ≤1×10¯¹³A/30min |
| Linear | ≥10⁷ |
| Sensitivity | S≥3000mv.ml/mg |
| Baseline Noise | ≤10µv |
| Baseline Drift | ≤30µv/30min |
| Linear | ≥10⁵ |
| Carrier gas velocity stability | ≤1% |
| Limit of detection | 5ׯ¹²g/s(S) (S in methyl parathion) |
| Linear range | 10⁵(P) 10³(S) |
| Maximum service temperature | 350°C |
| Detection Method | Air-hydrogen flame spectrometry |
| Optical detector | Top photomultiplier |
| Multiplier voltage | Max--700V |
| Limit of detection | ≤1×10¯¹⁴g/s |
| Linear range | 10⁴ |
| Source | Ni⁶³ |
| Limit of detection | (N)≤5×10¯¹²g/s |
| Power supply | 220 V ± 22 V, 50 Hz ± 0.5 Hz |
| Rated power | <1800 W |
| Ambient temperature | +5°C to +35°C |
| Relative humidity | ≤85% |
| Coal gas and biogas analysis (six components | H₂, O₂, N₂, CH₄, CO, and CO₂), featuring a unique single-valve sequential switching system |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelWhat this instrument is designed to do, in plain terms.
Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.
Ask for an itemised quotation that separates standard items from options.
See how the model is positioned for real measurement tasks.
Instrument selection for process support, incoming-material screening and release testing of chemical and material products.
8 measurement tasks · 7 instruments · 4 notes
Explore workflowLet’s talk about your application
Share your sample, measurement requirements and preferred configuration.