8 models

M Series Spectrophotometer

Eight spectrophotometers from M300 to M601S covering 190-1100 nm with plus or minus 0. 1 nm wavelength accuracy, photometric, quantitative and kinetics modes.

Category UV-Vis Spectrophotometer In production
M Series Spectrophotometer core specifications
Wavelength Accuracy ±0.1nm@656.1nm, ±0.3nm@all
Wavelength Repeatability ≤0.1nm
Photometric Accuracy ±0.2%T(0~100%T), ±0.0005A(0-0.5A), ±0.0008A(0.5-1A)

Send your sample type and method, and we will confirm the configuration and current lead time.

Ask about this model

sales@yoke-fac.com

Model comparison

M Series Spectrophotometer range at a glance

Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.

M Series Spectrophotometer — 8 models
ParameterM300M500M501M501SM400M600M601M601S
Optical SystemSingle Beam, Grating 1200 lines/mmSingle Beam, Grating 1200 lines/mmSingle Beam, Grating 1200 lines/mmSingle Beam, Grating 1200 lines/mmSplit Beam, Grating 1200 lines/mmDouble Beam, Grating 1200 lines/mmDouble Beam, Grating 1200 lines/mmDouble Beam, Grating 1200 lines/mm
Wavelength Range320-1100 nm190-1100 nm190-1100 nm190-1100 nm190-1100 nm190-1100 nm190-1100 nm190-1100 nm
Spectral Bandwidth2nm2nm1nm0.5/1/2/4/5nm2nm2nm1nm0.5/1/2/4/5nm
Wavelength Accuracy±0.1nm@656.1nm, ±0.3nm@all±0.1nm@656.1nm, ±0.3nm@all±0.1nm@656.1nm, ±0.3nm@all±0.1nm@656.1nm, ±0.3nm@all±0.1nm@656.1nm, ±0.3nm@all±0.1nm@656.1nm, ±0.3nm@all±0.1nm@656.1nm, ±0.3nm@all±0.1nm@656.1nm, ±0.3nm@all
Wavelength Repeatability≤0.1nm≤0.1nm≤0.1nm≤0.1nm≤0.1nm≤0.1nm≤0.1nm≤0.1nm
Photometric Accuracy±0.2%T(0~100%T), ±0.0005A(0-0.5A), ±0.0008A(0.5-1A)±0.2%T(0~100%T), ±0.0005A(0-0.5A), ±0.0008A(0.5-1A)±0.2%T(0~100%T), ±0.0005A(0-0.5A), ±0.0008A(0.5-1A)±0.2%T(0~100%T), ±0.0005A(0-0.5A), ±0.0008A(0.5-1A)±0.2%T(0~100%T), ±0.0005A(0-0.5A), ±0.0008A(0.5-1A)±0.2%T(0~100%T), ±0.0005A(0-0.5A), ±0.0008A(0.5-1A)±0.2%T(0~100%T), ±0.0005A(0-0.5A), ±0.0008A(0.5-1A)±0.2%T(0~100%T), ±0.0005A(0-0.5A), ±0.0008A(0.5-1A)
Photometric Repeatability≤0.15%T (0-100%T), 0.0004A(0-0.5A), 0.0006A(0.5-1A)≤0.15%T (0-100%T), 0.0004A(0-0.5A), 0.0006A(0.5-1A)≤0.15%T (0-100%T), 0.0004A(0-0.5A), 0.0006A(0.5-1A)≤0.15%T (0-100%T), 0.0004A(0-0.5A), 0.0006A(0.5-1A)≤0.15%T (0-100%T), 0.0004A(0-0.5A), 0.0006A(0.5-1A)≤0.15%T (0-100%T), 0.0004A(0-0.5A), 0.0006A(0.5-1A)≤0.15%T (0-100%T), 0.0004A(0-0.5A), 0.0006A(0.5-1A)≤0.15%T (0-100%T), 0.0004A(0-0.5A), 0.0006A(0.5-1A)
Photometric Range0-400%T, -4~4A0-400%T, -4~4A0-400%T, -4~4A0-400%T, -4~4A0-400%T, -4~4A0-400%T, -4~4A0-400%T, -4~4A0-400%T, -4~4A
Resolution0.00001Abs0.00001Abs0.00001Abs0.00001Abs0.00001Abs0.00001Abs0.00001Abs0.00001Abs
Stray Light≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm
Stability±0.0001A±0.0001A±0.0001A±0.0001A±0.0001A±0.0001A±0.0001A±0.0001A
Baseline Flatness±0.0004A±0.0004A±0.0004A±0.0004A±0.0004A±0.0004A±0.0004A±0.0004A
Noise0.0005A@500nm0.0005A@500nm0.0005A@500nm0.0005A@500nm0.0005A@500nm0.0005A@500nm0.0005A@500nm0.0005A@500nm
Work ModeT, A, C, ET, A, C, ET, A, C, ET, A, C, ET, A, C, ET, A, C, ET, A, C, ET, A, C, E
Scanning SpeedHi, Med, Low (Max. 8000nm/min)Hi, Med, Low (Max. 8000nm/min)Hi, Med, Low (Max. 8000nm/min)Hi, Med, Low (Max. 8000nm/min)Hi, Med, Low (Max. 8000nm/min)Hi, Med, Low (Max. 8000nm/min)Hi, Med, Low (Max. 8000nm/min)Hi, Med, Low (Max. 8000nm/min)
Display11-inch Touch Screen11-inch Touch Screen11-inch Touch Screen11-inch Touch Screen11-inch Touch Screen11-inch Touch Screen11-inch Touch Screen11-inch Touch Screen
Light SourceTungsten LampDeuterium & Tungsten LampDeuterium & Tungsten LampDeuterium & Tungsten LampDeuterium & Tungsten LampDeuterium & Tungsten LampDeuterium & Tungsten LampDeuterium & Tungsten Lamp
DetectorSilicon PhotodiodeSilicon PhotodiodeSilicon PhotodiodeSilicon PhotodiodeSilicon PhotodiodeSilicon PhotodiodeSilicon PhotodiodeSilicon Photodiode
Cuvette Holder10mm manual 4-cell holder10mm manual 4-cell holder10mm manual 4-cell holder10mm manual 4-cell holder10mm manual 4-cell holder10mm single hole cell holder10mm single hole cell holder10mm single hole cell holder
OutputCloud connectivity/Email/SMS/Bluetooth/WiFiCloud connectivity/Email/SMS/Bluetooth/WiFiCloud connectivity/Email/SMS/Bluetooth/WiFiCloud connectivity/Email/SMS/Bluetooth/WiFiCloud connectivity/Email/SMS/Bluetooth/WiFiCloud connectivity/Email/SMS/Bluetooth/WiFiCloud connectivity/Email/SMS/Bluetooth/WiFiCloud connectivity/Email/SMS/Bluetooth/WiFi
PowerAC 110-220V 50-60HzAC 110-220V 50-60HzAC 110-220V 50-60HzAC 110-220V 50-60HzAC 110-220V 50-60HzAC 110-220V 50-60HzAC 110-220V 50-60HzAC 110-220V 50-60Hz

Shaded labels mark the specifications that differ between models.

Overview

What this instrument is designed to do, in plain terms.

The M Series Spectrophotometer covers 8 models, M300 to M601S. The comparison table lists the values that differ across the range.

  • 11-inch Touch Screen
  • Functions include Photometric measurement, Quantitative measurement, Kinetics, Spectrum scan, DNA/Protein test, Multi-wavelength test, etc.
  • Equipped with GLP/GMP functions, including user management, audit tracking, log inquiry, etc.
  • Support real-time sending of data via email and mobile SMS.
  • Adopts 3. 0 Bluetooth protocol, with stable transmission and free interconnection within 10 meters.
  • Can be directly connected to laser printer via WiFi and thermal printer via Bluetooth.
  • Extensive accessories are optional, such as auto 4-cell/5-cell/8-cell holder, film holder, tube rack, integrating sphere, reflection accessory, peltier/sipper system, 21 CFR compliant software, etc.

Accessaries

Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.

Standard Accessaries

  • 10mm glass cuvette x 4
  • 10mm quartz cuvette(UV) x 2
  • Power cord
  • User's Manual

Optional Accessaries

  • auto 4-cell/5-cell/8-cell holder
  • film holder
  • tube rack
  • integrating sphere
  • reflection accessory
  • peltier/sipper system
  • 21 CFR compliant software
Specifications can depend on the selected configuration. Confirm the current datasheet, accessories and software version before purchase.

Product documentation

No public documents are linked to this model yet.

Request current documents

Let’s talk about your application

Find the right instrument for your application.

Share your sample, measurement requirements and preferred configuration.

Contact our team