2 models
Fluorescence Spectrophotometer F968/F980
The interface adopts partitioned modular layout with intuitive function icons.
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents- Both excitation and emission spectra cover a continuous range from 200 nm to 900 nm, accommodating most fluorescence analysis applications.
- Supports overlay display of multiple spectra for comparison between standard samples and test samples as well as variation analysis among different batches; spectrum subtraction and ratio calculation…
- The bundled software supports multiple advanced modes including 3D fluorescence scanning, constant wavelength difference synchronous scanning and constant wavenumber difference synchronous scanning.
- The bundled software is embedded with limit of detection (LOD) test function, which automatically completes sensitivity verification for low-concentration samples and quickly determines the method’s…
- The audit trail function of the matching PC software automatically records full-process immutable data, fully complying with regulatory requirements including FDA 21 CFR Part 11 and PIC/S GMP.
| Light Source | High-intensity ozone-removing xenon lamp |
|---|---|
| Optical System | C-T double monochromator grating |
| Fluorescence Detector | Original Hamamatsu photomultiplier tube (PMT) |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelModel comparison
Fluorescence Spectrophotometer F968/F980 range at a glance
Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.
| Parameter | F968 | F980 |
|---|---|---|
| Light Source | High-intensity ozone-removing xenon lamp | High-intensity ozone-removing xenon lamp |
| Optical System | C-T double monochromator grating | C-T double monochromator grating |
| Fluorescence Detector | Original Hamamatsu photomultiplier tube (PMT) | Original Hamamatsu photomultiplier tube (PMT) |
| Excitation Wavelength Range | 200–900 nm | 200–900 nm |
| Excitation/ Emission Bandwidth | 10nm | 1nm/2nm/5nm/10nm/20nm |
| Emission Wavelength Range | 200-900nm | 200-900nm |
| Emission Wavelength Accuracy | ±1.0nm | ±0.4nm |
| Emission Wavelength Repeatability | ≤0.5nm | ≤0.2nm |
| Wavelength Scanning Speed | 5 speeds: Ultra-fast, Fast, Medium, Slow, Ultra-slow | 5 speeds: Ultra-fast, Fast, Medium, Slow, Ultra-slow |
| Detection Sensitivity (SNR) | S/N ≥90 (P-P) | S/N ≥90 (P-P) |
| Peak Intensity Repeatability | ≤1.5% | ≤1.5% |
| Measurement Linearity | Correlation coefficient ≥ 0.995 | Correlation coefficient ≥ 0.995 |
| Data Transmission Mode | RS232 serial port, USB-B, USB-A | RS232 serial port, USB-B, USB-A |
| PC Software | Optional (optional 21 CFR compliant software) | Optional (optional 21 CFR compliant software) |
| Power | 220V/50HZ | 220V/50HZ |
Shaded labels mark the specifications that differ between models.
Overview
What this instrument is designed to do, in plain terms.
The Fluorescence Spectrophotometer F968/F980 covers 2 models, F968 to F980. The comparison table lists the values that differ across the range.
- The interface adopts partitioned modular layout with intuitive function icons. The main screen integrates core functions including spectrum scanning, quantitative analysis and method management, and displays real-time instrument operating parameters; an independent module for data archiving and audit trail is arranged on the right.
- Both excitation and emission spectra cover a continuous range from 200 nm to 900 nm, accommodating most fluorescence analysis applications. It features a six-order-of-magnitude photometric detection range with wide dynamic performance to suit the analysis of various complex samples.
- Supports overlay display of multiple spectra for comparison between standard samples and test samples as well as variation analysis among different batches; spectrum subtraction and ratio calculation are available.
- The bundled software supports multiple advanced modes including 3D fluorescence scanning, constant wavelength difference synchronous scanning and constant wavenumber difference synchronous scanning.
- The bundled software is embedded with limit of detection (LOD) test function, which automatically completes sensitivity verification for low-concentration samples and quickly determines the method’s lower detection limit. A blocking shutter is installed on the excitation side to shorten sample exposure duration and safeguard photosensitive samples. A gated optical shutter is equipped on the emission side to avoid direct intense light irradiation onto the detector and prolong its service life.
- The audit trail function of the matching PC software automatically records full-process immutable data, fully complying with regulatory requirements including FDA 21 CFR Part 11 and PIC/S GMP. Integrated intelligent verification technology automatically identifies and alerts against data tampering, complemented by graded user permission and operation traceability modules.
Accessaries
Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.
Standard Accessaries
Ask for an itemised quotation that separates standard items from options.
Optional Accessaries
- PC software
- 21 CFR compliant software
Let’s talk about your application
Find the right instrument for your application.
Share your sample, measurement requirements and preferred configuration.