2 models

Fluorescence Spectrophotometer F968/F980

The interface adopts partitioned modular layout with intuitive function icons.

Category Fluorescence Spectrophotometer In production
  • Both excitation and emission spectra cover a continuous range from 200 nm to 900 nm, accommodating most fluorescence analysis applications.
  • Supports overlay display of multiple spectra for comparison between standard samples and test samples as well as variation analysis among different batches; spectrum subtraction and ratio calculation…
  • The bundled software supports multiple advanced modes including 3D fluorescence scanning, constant wavelength difference synchronous scanning and constant wavenumber difference synchronous scanning.
  • The bundled software is embedded with limit of detection (LOD) test function, which automatically completes sensitivity verification for low-concentration samples and quickly determines the method’s…
  • The audit trail function of the matching PC software automatically records full-process immutable data, fully complying with regulatory requirements including FDA 21 CFR Part 11 and PIC/S GMP.
Fluorescence Spectrophotometer F968/F980 core specifications
Light Source High-intensity ozone-removing xenon lamp
Optical System C-T double monochromator grating
Fluorescence Detector Original Hamamatsu photomultiplier tube (PMT)

Send your sample type and method, and we will confirm the configuration and current lead time.

Ask about this model

sales@yoke-fac.com

Model comparison

Fluorescence Spectrophotometer F968/F980 range at a glance

Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.

Fluorescence Spectrophotometer F968/F980 — 2 models
ParameterF968F980
Light SourceHigh-intensity ozone-removing xenon lampHigh-intensity ozone-removing xenon lamp
Optical SystemC-T double monochromator gratingC-T double monochromator grating
Fluorescence DetectorOriginal Hamamatsu photomultiplier tube (PMT)Original Hamamatsu photomultiplier tube (PMT)
Excitation Wavelength Range200–900 nm200–900 nm
Excitation/ Emission Bandwidth10nm1nm/2nm/5nm/10nm/20nm
Emission Wavelength Range200-900nm200-900nm
Emission Wavelength Accuracy±1.0nm±0.4nm
Emission Wavelength Repeatability≤0.5nm≤0.2nm
Wavelength Scanning Speed5 speeds: Ultra-fast, Fast, Medium, Slow, Ultra-slow5 speeds: Ultra-fast, Fast, Medium, Slow, Ultra-slow
Detection Sensitivity (SNR)S/N ≥90 (P-P)S/N ≥90 (P-P)
Peak Intensity Repeatability≤1.5%≤1.5%
Measurement LinearityCorrelation coefficient ≥ 0.995Correlation coefficient ≥ 0.995
Data Transmission ModeRS232 serial port, USB-B, USB-ARS232 serial port, USB-B, USB-A
PC SoftwareOptional (optional 21 CFR compliant software)Optional (optional 21 CFR compliant software)
Power220V/50HZ220V/50HZ

Shaded labels mark the specifications that differ between models.

Overview

What this instrument is designed to do, in plain terms.

The Fluorescence Spectrophotometer F968/F980 covers 2 models, F968 to F980. The comparison table lists the values that differ across the range.

  • The interface adopts partitioned modular layout with intuitive function icons. The main screen integrates core functions including spectrum scanning, quantitative analysis and method management, and displays real-time instrument operating parameters; an independent module for data archiving and audit trail is arranged on the right.
  • Both excitation and emission spectra cover a continuous range from 200 nm to 900 nm, accommodating most fluorescence analysis applications. It features a six-order-of-magnitude photometric detection range with wide dynamic performance to suit the analysis of various complex samples.
  • Supports overlay display of multiple spectra for comparison between standard samples and test samples as well as variation analysis among different batches; spectrum subtraction and ratio calculation are available.
  • The bundled software supports multiple advanced modes including 3D fluorescence scanning, constant wavelength difference synchronous scanning and constant wavenumber difference synchronous scanning.
  • The bundled software is embedded with limit of detection (LOD) test function, which automatically completes sensitivity verification for low-concentration samples and quickly determines the method’s lower detection limit. A blocking shutter is installed on the excitation side to shorten sample exposure duration and safeguard photosensitive samples. A gated optical shutter is equipped on the emission side to avoid direct intense light irradiation onto the detector and prolong its service life.
  • The audit trail function of the matching PC software automatically records full-process immutable data, fully complying with regulatory requirements including FDA 21 CFR Part 11 and PIC/S GMP. Integrated intelligent verification technology automatically identifies and alerts against data tampering, complemented by graded user permission and operation traceability modules.

Accessaries

Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.

Standard Accessaries

Ask for an itemised quotation that separates standard items from options.

Optional Accessaries

  • PC software
  • 21 CFR compliant software
Specifications can depend on the selected configuration. Confirm the current datasheet, accessories and software version before purchase.