FP-D Series Intelligent Flame Photometer

Built-in Oil-Free Air Compressor: No external air compressor required; plug-and-play operation saves laboratory space.

Category Flame Photometer In production
FP-D Series Intelligent Flame Photometer core specifications
Display 7-inch color touch screen
Display Results Concentration value/Energy
Reading Range 0.000~99999.999/0~65535

Send your sample type and method, and we will confirm the configuration and current lead time.

Ask about this model

sales@yoke-fac.com

Model comparison

FP-D Series Intelligent Flame Photometer range at a glance

Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.

FP-D Series Intelligent Flame Photometer — 7 models
ParameterFP6450DFP6440DFP6432DFP6431DFP6430DFP6410DFP6400D
Display7-inch color touch screen7-inch color touch screen7-inch color touch screen7-inch color touch screen7-inch color touch screen7-inch color touch screen7-inch color touch screen
Display ResultsConcentration value/EnergyConcentration value/EnergyConcentration value/EnergyConcentration value/EnergyConcentration value/EnergyConcentration value/EnergyConcentration value/Energy
Reading Range0.000~99999.999/0~655350.000~99999.999/0~655350.000~99999.999/0~655350.000~99999.999/0~655350.000~99999.999/0~655350.000~99999.999/0~655350.000~99999.999/0~65535
TestableK, Na, Li, Ca, BaK, Na, Li, CaK, Na, BaK, Na, CaK, Na, LiK, NaK, Na
Channel Qty5433322
Detection Limit ppm≤0.004; ≤0.008; ≤0.015; ≤0.050; ≤0.044≤0.004; ≤0.008; ≤0.015; ≤0.050; ——≤0.004; ≤0.008; ——; ——; ≤0.044≤0.004; ≤0.008; ——; ≤0.050; ——≤0.004; ≤0.008; ≤0.015; ——; ——≤0.004; ≤0.008; ——; ——; ——≤0.004; ≤0.008; ——; ——; ——
Linear Error≤0.005; ≤0.03; ≤0.021; ≤0.075; ≤0.066≤0.005; ≤0.03; ≤0.021; ≤0.075; ——≤0.005; ≤0.03; ——; ——; ≤0.066≤0.005; ≤0.03; ——; ≤0.075; ——≤0.005; ≤0.03; ≤0.021; ——; ——≤0.005; ≤0.03; ——; ——; ——≤0.005; ≤0.03; ——; ——; ——
Response Time<8S<8S<8S<8S<8S<8S<8S
Sample Uptake<6ml/min<6ml/min<6ml/min<6ml/min<6ml/min<6ml/min<6ml/min
StabilityContinuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.
Reproducibility≤3% coefficient of variation for 7 consecutive samples≤3% coefficient of variation for 7 consecutive samples≤3% coefficient of variation for 7 consecutive samples≤3% coefficient of variation for 7 consecutive samples≤3% coefficient of variation for 7 consecutive samples≤3% coefficient of variation for 7 consecutive samples≤3% coefficient of variation for 7 consecutive samples
Bluetooth PrinterYesYesYesYesYesYesNo
OutputUSB portUSB portUSB portUSB portUSB portUSB portUSB port
PowerAC 220V/50Hz or AC 110V/60HzAC 220V/50Hz or AC 110V/60HzAC 220V/50Hz or AC 110V/60HzAC 220V/50Hz or AC 110V/60HzAC 220V/50Hz or AC 110V/60HzAC 220V/50Hz or AC 110V/60HzAC 220V/50Hz or AC 110V/60Hz

Overview

What this instrument is designed to do, in plain terms.

The FP-D Series Intelligent Flame Photometer covers 7 models, FP6450D to FP6400D. The comparison table lists the values that differ across the range.

  • Built-in Oil-Free Air Compressor: No external air compressor required; plug-and-play operation saves laboratory space.
  • Gas Leak Alarm System: Real-time monitoring of gas status with automatic alarms in case of abnormalities.
  • Multiple Safety Protections: Automatic ignition, flame-out protection, and gas circuit abnormality alarm.
  • Supports PC software operation, USB storage, printing, and historical data traceability.
  • High-Stability Detection Performance: Fast response, excellent repeatability, and stable long-term operation.

Accessaries

Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.

Standard Accessaries

Ask for an itemised quotation that separates standard items from options.

Optional Accessaries

No Optional Accessaries are published for this model. Confirm availability with our team.

Specifications can depend on the selected configuration. Confirm the current datasheet, accessories and software version before purchase.

Product documentation

No public documents are linked to this model yet.

Request current documents

Let’s talk about your application

Find the right instrument for your application.

Share your sample, measurement requirements and preferred configuration.

Contact our team