AA Series

AA 7804 Flame Atomic Absorption Spectrometer

Flame atomic absorption spectrometer with a Czerny-Turner monochromator, automated 0. 1-2. 0 nm slit selection and a 190-900 nm wavelength range.

Model AA 7804 Category Atomic Absorption Spectrometer In production
  • Comprehensive and safe intelligent gas control module.
  • Excellent full band deuterium lamp background correction technology and high-performance self absorption double background correction.
  • Fully automatic instrument control, light source supports high-performance element lamp, and can be completed quickly with one key.
  • Original lamp position eight lamp holder 360 degree rotation design.
  • Novel atomizer and intelligent elevator.
AA 7804 core specifications
Optical System Single Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Holographic diffraction with 1800 lines/mm
Wavelength Range 190-900 nm
Slits Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm
Wavelength Repeatability ±0.1nm
Wavelength Accuracy ±0.3 nm
Lamp Automated 4-lamp turret
Reading Mode T, A, C
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ≤0.004A/30 min
Dynamic Baseline Drift (Cu) ≤0.006A/15 min
Background Correction Deuterium (D2) Background Correction
Flame · Characteristic Concentration ≤0.04ug/ml
Flame · Detection Limit (Cu) ≤0.008ug/ml
Flame · Repeatability (Cu) RSD≤1%
Flame · Acetylene Flow Control Auto 12-Level
Flame · Air Assist Control Auto 4-Level
Flame · Ignition Method PC control
Flame · Detector Wide range UV sensitive photomultiplier tube
Flame · Burner Head Titanium 100mm burner for air/acetylene operation
Flame · Nebulizer High efficiency glass nebulizer
Flame · Spray Chamber Corrosion resistant material spray chamber
Flame · Safety Protection Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Data Processing · Measuring method Flame method, Hydride generation-Atomic absorption method, Flame emission method
Data Processing · Concentration calculation method Standard curve method (6 linear/non-linear fitting methods), Standard addition method, Interpolation method
Data Processing · Repeat measurement times 1-30 times, Calculate and give the average value of absorbance/concentration, standard deviation and relative standard deviation
Data Processing · Report printing Parameter printing, Data result printing
Dimensions / Weight 850 x 650 x 550 mm/95kg
Ambient Temp. 10 ~ 35 °C
Ambient Humidity ≦85 %
Power 110/220V, 50/60Hz

Send your sample type and method, and we will confirm the configuration and current lead time.

Ask about this model

sales@yoke-fac.com

Overview

What this instrument is designed to do, in plain terms.

AA

  • Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.
  • Comprehensive and safe intelligent gas control module.
  • Excellent full band deuterium lamp background correction technology and high-performance self absorption double background correction.
  • Fully automatic instrument control, light source supports high-performance element lamp, and can be completed quickly with one key.
  • Original lamp position eight lamp holder 360 degree rotation design.
  • Novel atomizer and intelligent elevator.
  • Simple, professional, automatic and fully operated RG WIN AAS workstation software under MS window system.

Accessaries

Confirm these items before the final quotation. Accessaries are listed only where the manufacturer offers them.

Standard Accessaries

Ask for an itemised quotation that separates standard items from options.

Optional Accessaries

No Optional Accessaries are published for this model. Confirm availability with our team.

Specifications can depend on the selected configuration. Confirm the current datasheet, accessories and software version before purchase.

Product documentation

No public documents are linked to this model yet.

Request current documents

Let’s talk about your application

Find the right instrument for your application.

Share your sample, measurement requirements and preferred configuration.

Contact our team